Three-phase Water-cooling Permanent Magnet Synchronous Motor

The three-phase water-cooled permanent magnet synchronous motor is designed to deliver the good performance characteristics of permanent magnet motors, encompassing both high-speed and low-speed variants. These motors are specifically engineered to thrive in high-temperature environments, thanks to their innovative closed-loop water cooling system that can withstand high temperatures and humidity levels. They are ideally suited for applications in various industries, including military, metallurgy, steel, rubber, and pharmaceuticals, where traditional fan cooling methods may not be feasible.

Product details

Feature

1. High power density and compact design, with an impressive overload capacity;
2. Good heat dissipation capabilities, offering a tenfold improvement over air-cooled motors;
3. Compact size, lightweight construction, and low noise levels;
4. Robust sealing to protect against dust and debris;
5. Retains the inherent performance advantages of permanent magnet synchronous motors.

Specification

 

TJY-132-6
Speed r/minModelPower kWTorque N.mCurrent AVoltage VFrequency HzProtection ClassInsulation Class
1000TJY-132-1000-151514326.238050IP54F
TJY-132-1000-202019138.538050IP54F
TJY-132-1000-2525238.74338050IP54F
TJY-132-1000-3030286.551.638050IP54F
TJY-132-1000-37373536538050IP54F
1500TJY-132-1500-222214038.738075IP54F
TJY-132-1500-303019150.438075IP54F
TJY-132-1500-3737235.564.738075IP54F
TJY-132-1500-4545286.58138075IP54F
TJY-132-1500-555535096.438075IP54F
3000TJY-132-3000-303095.560.2380150IP54F
TJY-132-3000-4141130.576.8380150IP54F
TJY-132-3000-5252165.595.6380150IP54F
TJY-132-3000-6363200.5115380150IP54F
TJY-132-3000-7878248155380150IP54F

 

TJY-160-8
Speed r/minModelPower kWTorque N.mCurrent AVoltage VFrequency HzProtection ClassInsulation Class
1000TJY-160-1000-24.524.523441.538066.7IP54F
TJY-160-1000-3030286.550.638066.7IP54F
TJY-160-1000-35.535.53396038066.7IP54F
TJY-160-1000-43.543.54157338066.7IP54F
TJY-160-1000-494946882.338066.7IP54F
TJY-160-1000-606057310138066.7IP54F
1500TJY-160-1500-373723562380100IP54F
TJY-160-1500-4545286.571380100IP54F
TJY-160-1500-555535087380100IP54F
TJY-160-1500-6565413.8103380100IP54F
TJY-160-1500-7575477.5120380100IP54F
TJY-160-1500-9090573148380100IP54F
3000TJY-160-3000-555517593380200IP54F
TJY-160-3000-6565207104380200IP54F
TJY-160-3000-8080254.6129380200IP54F
TJY-160-3000-9595302.4156380200IP54F
TJY-160-3000-110110350183380200IP54F
TJY-160-3000-130130413.8234380200IP54F

 

TJY-200-8
Speed r/minModelPower kWTorque N.mCurrent AVoltage VFrequency HzProtection ClassInsulation Class
1000TJY-200-1000-5050477.58238066.7IP54F
TJY-200-1000-60605739738066.7IP54F
TJY-200-1000-757571612338066.7IP54F
TJY-200-1000-909086015038066.7IP54F
TJY-2000-1000-106106101217438066.7IP54F
TJY-200-1000-120120114618938066.7IP54F
1500TJY-200-1500-7575477.5123380100IP54F
TJY-200-1500-9090573145380100IP54F
TJY-200-1500-110110700180380100IP54F
TJY-200-1500-132132840220380100IP54F
TJY-200-1500-1601601018261380100IP54F
TJY-200-1500-1801801146284380100IP54F
3000TJY-200-3000-110110350180380200IP54F
TJY-200-3000-132132420212380200IP54F
TJY-200-3000-160160510262380200IP54F
TJY-200-3000-200200636.6333380200IP54F
TJY-200-3000-240240764391380200IP54F
TJY-200-3000-300300955473380200IP54F
Buyer Decision Guide

What Engineers Should Confirm for This Configuration

The final configuration depends on motor losses, cooling-loop conditions and the real torque-speed profile. Cooling performance must not be assumed without engineering review.

The specifications and included components for this exact product are described above. The guidance below supports sourcing decisions; it is not a claim that every option or capability is available for this SKU.

01

Operating Torque

Define continuous and peak shaft-load demand.

02

Speed & Drive

Confirm normal speed, limits and inverter requirements.

03

Coolant Conditions

Supply fluid, inlet temperature, available flow and pressure conditions.

04

Heat Rejection

Check ambient and thermal duty over the operating cycle.

05

Connections & Space

Review coolant ports, shaft and mounting envelope.

06

Testing & Protection

Identify leak, temperature, insulation and operating checks needed.

Customization & Application & System Fit

Confirm the Operating Conditions Before Quotation

Mechanical interfaces, operating duty, cooling and controls affect whether a configuration is suitable. Use the actual model information when discussing project requirements.

Thermal Duty

Define continuous load and expected heat-removal conditions.

Coolant Interface

Check available coolant temperature, flow and connection constraints.

System Controls

Verify motor-inverter operating points across the speed range.

Mechanical Integration

Confirm mounting, pipe access and equipment footprint.

Engineering Evidence & Compliance

Verify Cooling, Electrical Protection and Testing Requirements

Confirm the final proposed model, coolant specifications and required tests rather than extrapolating from catalog photographs or other models.

Technical Documentation

Ask for applicable model ratings and outline drawings.

Verification

Define tests and acceptance criteria appropriate to the application.

Shipment Planning

Confirm packaging, handling and destination requirements.

RFQ Minimum Input

What to Send for Technical Evaluation

Provide the following operating and integration details so the proposed configuration can be evaluated.

  1. Product reference or application description
  2. Required operating duty and load
  3. Electrical or mechanical interface details
  4. Site environment and installation constraints
  5. Required tests and technical documentation
  6. Quantity, destination and project timeline
Engineering Review & Delivery

From Application Review to Production Confirmation

A practical engineering procurement sequence depends on defining the application, reviewing a suitable configuration and agreeing the evidence required.

01

Requirement Review

Send application and technical data.

02

Configuration Discussion

Review candidate models, interfaces and constraints.

03

Sample & Validation

Agree drawings, tests and acceptance criteria if required.

04

Production & Delivery

Confirm quotation, scope, inspection and shipment details.

Operating limits, documented ratings, test evidence, delivery scope and quotation terms must be confirmed for the exact configuration.

Engineering Inquiry

Discuss Your Motor or Magnetic Project

Share your intended application, torque or load requirements, operating conditions, interface drawings and project timing.

Shopping Cart