Three-phase Water-cooling Permanent Magnet Synchronous Motor

The three-phase water-cooled permanent magnet synchronous motor is designed to deliver the good performance characteristics of permanent magnet motors, encompassing both high-speed and low-speed variants. These motors are specifically engineered to thrive in high-temperature environments, thanks to their innovative closed-loop water cooling system that can withstand high temperatures and humidity levels. They are ideally suited for applications in various industries, including military, metallurgy, steel, rubber, and pharmaceuticals, where traditional fan cooling methods may not be feasible.

Product details

Feature

1. High power density and compact design, with an impressive overload capacity;
2. Good heat dissipation capabilities, offering a tenfold improvement over air-cooled motors;
3. Compact size, lightweight construction, and low noise levels;
4. Robust sealing to protect against dust and debris;
5. Retains the inherent performance advantages of permanent magnet synchronous motors.

Specification

 

TJY-132-6
Speed r/min Model Power kW Torque N.m Current A Voltage V Frequency Hz Protection Class Insulation Class
1000 TJY-132-1000-15 15 143 26.2 380 50 IP54 F
TJY-132-1000-20 20 191 38.5 380 50 IP54 F
TJY-132-1000-25 25 238.7 43 380 50 IP54 F
TJY-132-1000-30 30 286.5 51.6 380 50 IP54 F
TJY-132-1000-37 37 353 65 380 50 IP54 F
1500 TJY-132-1500-22 22 140 38.7 380 75 IP54 F
TJY-132-1500-30 30 191 50.4 380 75 IP54 F
TJY-132-1500-37 37 235.5 64.7 380 75 IP54 F
TJY-132-1500-45 45 286.5 81 380 75 IP54 F
TJY-132-1500-55 55 350 96.4 380 75 IP54 F
3000 TJY-132-3000-30 30 95.5 60.2 380 150 IP54 F
TJY-132-3000-41 41 130.5 76.8 380 150 IP54 F
TJY-132-3000-52 52 165.5 95.6 380 150 IP54 F
TJY-132-3000-63 63 200.5 115 380 150 IP54 F
TJY-132-3000-78 78 248 155 380 150 IP54 F

 

TJY-160-8
Speed r/min Model Power kW Torque N.m Current A Voltage V Frequency Hz Protection Class Insulation Class
1000 TJY-160-1000-24.5 24.5 234 41.5 380 66.7 IP54 F
TJY-160-1000-30 30 286.5 50.6 380 66.7 IP54 F
TJY-160-1000-35.5 35.5 339 60 380 66.7 IP54 F
TJY-160-1000-43.5 43.5 415 73 380 66.7 IP54 F
TJY-160-1000-49 49 468 82.3 380 66.7 IP54 F
TJY-160-1000-60 60 573 101 380 66.7 IP54 F
1500 TJY-160-1500-37 37 235 62 380 100 IP54 F
TJY-160-1500-45 45 286.5 71 380 100 IP54 F
TJY-160-1500-55 55 350 87 380 100 IP54 F
TJY-160-1500-65 65 413.8 103 380 100 IP54 F
TJY-160-1500-75 75 477.5 120 380 100 IP54 F
TJY-160-1500-90 90 573 148 380 100 IP54 F
3000 TJY-160-3000-55 55 175 93 380 200 IP54 F
TJY-160-3000-65 65 207 104 380 200 IP54 F
TJY-160-3000-80 80 254.6 129 380 200 IP54 F
TJY-160-3000-95 95 302.4 156 380 200 IP54 F
TJY-160-3000-110 110 350 183 380 200 IP54 F
TJY-160-3000-130 130 413.8 234 380 200 IP54 F

 

TJY-200-8
Speed r/min Model Power kW Torque N.m Current A Voltage V Frequency Hz Protection Class Insulation Class
1000 TJY-200-1000-50 50 477.5 82 380 66.7 IP54 F
TJY-200-1000-60 60 573 97 380 66.7 IP54 F
TJY-200-1000-75 75 716 123 380 66.7 IP54 F
TJY-200-1000-90 90 860 150 380 66.7 IP54 F
TJY-2000-1000-106 106 1012 174 380 66.7 IP54 F
TJY-200-1000-120 120 1146 189 380 66.7 IP54 F
1500 TJY-200-1500-75 75 477.5 123 380 100 IP54 F
TJY-200-1500-90 90 573 145 380 100 IP54 F
TJY-200-1500-110 110 700 180 380 100 IP54 F
TJY-200-1500-132 132 840 220 380 100 IP54 F
TJY-200-1500-160 160 1018 261 380 100 IP54 F
TJY-200-1500-180 180 1146 284 380 100 IP54 F
3000 TJY-200-3000-110 110 350 180 380 200 IP54 F
TJY-200-3000-132 132 420 212 380 200 IP54 F
TJY-200-3000-160 160 510 262 380 200 IP54 F
TJY-200-3000-200 200 636.6 333 380 200 IP54 F
TJY-200-3000-240 240 764 391 380 200 IP54 F
TJY-200-3000-300 300 955 473 380 200 IP54 F
Buyer Decision Guide

What Engineers Should Confirm for This Configuration

The final configuration depends on motor losses, cooling-loop conditions and the real torque-speed profile. Cooling performance must not be assumed without engineering review.

The specifications and included components for this exact product are described above. The guidance below supports sourcing decisions; it is not a claim that every option or capability is available for this SKU.

01

Operating Torque

Define continuous and peak shaft-load demand.

02

Speed & Drive

Confirm normal speed, limits and inverter requirements.

03

Coolant Conditions

Supply fluid, inlet temperature, available flow and pressure conditions.

04

Heat Rejection

Check ambient and thermal duty over the operating cycle.

05

Connections & Space

Review coolant ports, shaft and mounting envelope.

06

Testing & Protection

Identify leak, temperature, insulation and operating checks needed.

Customization & Application & System Fit

Confirm the Operating Conditions Before Quotation

Mechanical interfaces, operating duty, cooling and controls affect whether a configuration is suitable. Use the actual model information when discussing project requirements.

Thermal Duty

Define continuous load and expected heat-removal conditions.

Coolant Interface

Check available coolant temperature, flow and connection constraints.

System Controls

Verify motor-inverter operating points across the speed range.

Mechanical Integration

Confirm mounting, pipe access and equipment footprint.

Engineering Evidence & Compliance

Verify Cooling, Electrical Protection and Testing Requirements

Confirm the final proposed model, coolant specifications and required tests rather than extrapolating from catalog photographs or other models.

Technical Documentation

Ask for applicable model ratings and outline drawings.

Verification

Define tests and acceptance criteria appropriate to the application.

Shipment Planning

Confirm packaging, handling and destination requirements.

RFQ Minimum Input

What to Send for Technical Evaluation

Provide the following operating and integration details so the proposed configuration can be evaluated.

  1. Product reference or application description
  2. Required operating duty and load
  3. Electrical or mechanical interface details
  4. Site environment and installation constraints
  5. Required tests and technical documentation
  6. Quantity, destination and project timeline
Engineering Review & Delivery

From Application Review to Production Confirmation

A practical engineering procurement sequence depends on defining the application, reviewing a suitable configuration and agreeing the evidence required.

01

Requirement Review

Send application and technical data.

02

Configuration Discussion

Review candidate models, interfaces and constraints.

03

Sample & Validation

Agree drawings, tests and acceptance criteria if required.

04

Production & Delivery

Confirm quotation, scope, inspection and shipment details.

Operating limits, documented ratings, test evidence, delivery scope and quotation terms must be confirmed for the exact configuration.

Engineering Inquiry

Discuss Your Motor or Magnetic Project

Share your intended application, torque or load requirements, operating conditions, interface drawings and project timing.