Operating Torque
Define continuous and peak shaft-load demand.
The three-phase water-cooled permanent magnet synchronous motor is designed to deliver the good performance characteristics of permanent magnet motors, encompassing both high-speed and low-speed variants. These motors are specifically engineered to thrive in high-temperature environments, thanks to their innovative closed-loop water cooling system that can withstand high temperatures and humidity levels. They are ideally suited for applications in various industries, including military, metallurgy, steel, rubber, and pharmaceuticals, where traditional fan cooling methods may not be feasible.
1. High power density and compact design, with an impressive overload capacity;
2. Good heat dissipation capabilities, offering a tenfold improvement over air-cooled motors;
3. Compact size, lightweight construction, and low noise levels;
4. Robust sealing to protect against dust and debris;
5. Retains the inherent performance advantages of permanent magnet synchronous motors.
| TJY-132-6 | ||||||||
| Speed r/min | Model | Power kW | Torque N.m | Current A | Voltage V | Frequency Hz | Protection Class | Insulation Class |
| 1000 | TJY-132-1000-15 | 15 | 143 | 26.2 | 380 | 50 | IP54 | F |
| TJY-132-1000-20 | 20 | 191 | 38.5 | 380 | 50 | IP54 | F | |
| TJY-132-1000-25 | 25 | 238.7 | 43 | 380 | 50 | IP54 | F | |
| TJY-132-1000-30 | 30 | 286.5 | 51.6 | 380 | 50 | IP54 | F | |
| TJY-132-1000-37 | 37 | 353 | 65 | 380 | 50 | IP54 | F | |
| 1500 | TJY-132-1500-22 | 22 | 140 | 38.7 | 380 | 75 | IP54 | F |
| TJY-132-1500-30 | 30 | 191 | 50.4 | 380 | 75 | IP54 | F | |
| TJY-132-1500-37 | 37 | 235.5 | 64.7 | 380 | 75 | IP54 | F | |
| TJY-132-1500-45 | 45 | 286.5 | 81 | 380 | 75 | IP54 | F | |
| TJY-132-1500-55 | 55 | 350 | 96.4 | 380 | 75 | IP54 | F | |
| 3000 | TJY-132-3000-30 | 30 | 95.5 | 60.2 | 380 | 150 | IP54 | F |
| TJY-132-3000-41 | 41 | 130.5 | 76.8 | 380 | 150 | IP54 | F | |
| TJY-132-3000-52 | 52 | 165.5 | 95.6 | 380 | 150 | IP54 | F | |
| TJY-132-3000-63 | 63 | 200.5 | 115 | 380 | 150 | IP54 | F | |
| TJY-132-3000-78 | 78 | 248 | 155 | 380 | 150 | IP54 | F | |
| TJY-160-8 | ||||||||
| Speed r/min | Model | Power kW | Torque N.m | Current A | Voltage V | Frequency Hz | Protection Class | Insulation Class |
| 1000 | TJY-160-1000-24.5 | 24.5 | 234 | 41.5 | 380 | 66.7 | IP54 | F |
| TJY-160-1000-30 | 30 | 286.5 | 50.6 | 380 | 66.7 | IP54 | F | |
| TJY-160-1000-35.5 | 35.5 | 339 | 60 | 380 | 66.7 | IP54 | F | |
| TJY-160-1000-43.5 | 43.5 | 415 | 73 | 380 | 66.7 | IP54 | F | |
| TJY-160-1000-49 | 49 | 468 | 82.3 | 380 | 66.7 | IP54 | F | |
| TJY-160-1000-60 | 60 | 573 | 101 | 380 | 66.7 | IP54 | F | |
| 1500 | TJY-160-1500-37 | 37 | 235 | 62 | 380 | 100 | IP54 | F |
| TJY-160-1500-45 | 45 | 286.5 | 71 | 380 | 100 | IP54 | F | |
| TJY-160-1500-55 | 55 | 350 | 87 | 380 | 100 | IP54 | F | |
| TJY-160-1500-65 | 65 | 413.8 | 103 | 380 | 100 | IP54 | F | |
| TJY-160-1500-75 | 75 | 477.5 | 120 | 380 | 100 | IP54 | F | |
| TJY-160-1500-90 | 90 | 573 | 148 | 380 | 100 | IP54 | F | |
| 3000 | TJY-160-3000-55 | 55 | 175 | 93 | 380 | 200 | IP54 | F |
| TJY-160-3000-65 | 65 | 207 | 104 | 380 | 200 | IP54 | F | |
| TJY-160-3000-80 | 80 | 254.6 | 129 | 380 | 200 | IP54 | F | |
| TJY-160-3000-95 | 95 | 302.4 | 156 | 380 | 200 | IP54 | F | |
| TJY-160-3000-110 | 110 | 350 | 183 | 380 | 200 | IP54 | F | |
| TJY-160-3000-130 | 130 | 413.8 | 234 | 380 | 200 | IP54 | F | |
| TJY-200-8 | ||||||||
| Speed r/min | Model | Power kW | Torque N.m | Current A | Voltage V | Frequency Hz | Protection Class | Insulation Class |
| 1000 | TJY-200-1000-50 | 50 | 477.5 | 82 | 380 | 66.7 | IP54 | F |
| TJY-200-1000-60 | 60 | 573 | 97 | 380 | 66.7 | IP54 | F | |
| TJY-200-1000-75 | 75 | 716 | 123 | 380 | 66.7 | IP54 | F | |
| TJY-200-1000-90 | 90 | 860 | 150 | 380 | 66.7 | IP54 | F | |
| TJY-2000-1000-106 | 106 | 1012 | 174 | 380 | 66.7 | IP54 | F | |
| TJY-200-1000-120 | 120 | 1146 | 189 | 380 | 66.7 | IP54 | F | |
| 1500 | TJY-200-1500-75 | 75 | 477.5 | 123 | 380 | 100 | IP54 | F |
| TJY-200-1500-90 | 90 | 573 | 145 | 380 | 100 | IP54 | F | |
| TJY-200-1500-110 | 110 | 700 | 180 | 380 | 100 | IP54 | F | |
| TJY-200-1500-132 | 132 | 840 | 220 | 380 | 100 | IP54 | F | |
| TJY-200-1500-160 | 160 | 1018 | 261 | 380 | 100 | IP54 | F | |
| TJY-200-1500-180 | 180 | 1146 | 284 | 380 | 100 | IP54 | F | |
| 3000 | TJY-200-3000-110 | 110 | 350 | 180 | 380 | 200 | IP54 | F |
| TJY-200-3000-132 | 132 | 420 | 212 | 380 | 200 | IP54 | F | |
| TJY-200-3000-160 | 160 | 510 | 262 | 380 | 200 | IP54 | F | |
| TJY-200-3000-200 | 200 | 636.6 | 333 | 380 | 200 | IP54 | F | |
| TJY-200-3000-240 | 240 | 764 | 391 | 380 | 200 | IP54 | F | |
| TJY-200-3000-300 | 300 | 955 | 473 | 380 | 200 | IP54 | F | |
When evaluating heat removal and mounting constraints, consider other water-cooled motor configurations alongside the proposed motor specification.
The final configuration depends on motor losses, cooling-loop conditions and the real torque-speed profile. Cooling performance must not be assumed without engineering review.
The specifications and included components for this exact product are described above. The guidance below supports sourcing decisions; it is not a claim that every option or capability is available for this SKU.
Define continuous and peak shaft-load demand.
Confirm normal speed, limits and inverter requirements.
Supply fluid, inlet temperature, available flow and pressure conditions.
Check ambient and thermal duty over the operating cycle.
Review coolant ports, shaft and mounting envelope.
Identify leak, temperature, insulation and operating checks needed.
Mechanical interfaces, operating duty, cooling and controls affect whether a configuration is suitable. Use the actual model information when discussing project requirements.
Define continuous load and expected heat-removal conditions.
Check available coolant temperature, flow and connection constraints.
Verify motor-inverter operating points across the speed range.
Confirm mounting, pipe access and equipment footprint.
Confirm the final proposed model, coolant specifications and required tests rather than extrapolating from catalog photographs or other models.
Ask for applicable model ratings and outline drawings.
Define tests and acceptance criteria appropriate to the application.
Confirm packaging, handling and destination requirements.
Provide the following operating and integration details so the proposed configuration can be evaluated.
A practical engineering procurement sequence depends on defining the application, reviewing a suitable configuration and agreeing the evidence required.
Send application and technical data.
Review candidate models, interfaces and constraints.
Agree drawings, tests and acceptance criteria if required.
Confirm quotation, scope, inspection and shipment details.
Operating limits, documented ratings, test evidence, delivery scope and quotation terms must be confirmed for the exact configuration.
Share your intended application, torque or load requirements, operating conditions, interface drawings and project timing.