Area Classification
Identify the applicable gas or dust zone and equipment group.
The three-phase explosion-proof permanent magnet synchronous motor is a newly developed and designed explosion-proof permanent magnet synchronous motor based on a permanent magnet synchronous motor. This motor is not only efficient and energy-efficient, but also simple in structure, reliable in operation, and can completely replace YB2, YB3, and other blast-proof asynchronous motors. With the explosion-proof mark of Exd II BT4Gb, this motor can be applied to petroleum, chemical industry, grain and oil, paper-making, medicine, textile, and other flammable and explosive occasions.
The products have obtained the explosion-proof certificate issued by the National Centre for Supervision and Inspection of the Quality of Explosion-proof Electrical Products and the production license issued by the State Bureau of Quality and Technical Supervision.
Feature
Conditions of Use
Ambient temperature: -15℃~40
Altitude: not more than 1000 meters
Rated voltage: 380V, 660V, other voltages are optional.
Rated frequency: 50Hz, 60Hz, other frequencies are optional.
Working system: continuous working system (S1)
Protection class: IP55
Insulation grade: F
Cooling method: IC411/IC416
Connection method: Y
| Motor Model | Rated Output kW | Rated Current | Rated Torque | Efficiency (%) | Power Factor | Rated speed | Rated Frequency Hz |
| TBYC-801-2 | 0.75 | 1.3 | 2.4 | 84.9 | 0.95 | 3000 | 100 |
| TBYC-802-2 | 1.1 | 1.9 | 3.5 | 86.7 | 0.95 | 3000 | 100 |
| TBYC-90S-2 | 1.5 | 2.4 | 4.7 | 87.5 | 0.95 | 3000 | 100 |
| TBYC-90L-2 | 2.2 | 3.8 | 7 | 89.1 | 0.95 | 3000 | 100 |
| TBYC-100L-2 | 3 | 5.1 | 9.5 | 89.7 | 0.95 | 3000 | 100 |
| TBYC-112M-2 | 4 | 6.6 | 12.7 | 90.3 | 0.95 | 3000 | 100 |
| TBYC-132S1-2 | 5.5 | 9.2 | 17.5 | 91.5 | 0.95 | 3000 | 100 |
| TBYC-132S2-2 | 7.5 | 10.9 | 23.8 | 92.1 | 0.95 | 3000 | 100 |
| TBYC-160M1-2 | 11 | 19.5 | 35 | 93 | 0.95 | 3000 | 150 |
| TBYC-160M2-2 | 15 | 26.7 | 47.7 | 93.4 | 0.95 | 3000 | 150 |
| TBYC-160L-2 | 18.5 | 32 | 58.9 | 93.8 | 0.95 | 3000 | 200 |
| TBYC-180M-2 | 22 | 37.4 | 70 | 94.4 | 0.95 | 3000 | 200 |
| TBYC-200L1-2 | 30 | 51 | 95.5 | 94.5 | 0.95 | 3000 | 200 |
| TBYC-200L2-2 | 37 | 61.3 | 117.8 | 94.8 | 0.95 | 3000 | 200 |
| TBYC-225M-2 | 45 | 75 | 143.3 | 95.1 | 0.95 | 3000 | 200 |
| TBYC-250M-2 | 55 | 95 | 175 | 95.4 | 0.95 | 3000 | 100 |
| TBYC-280S-2 | 75 | 125 | 238.7 | 95.6 | 0.95 | 3000 | 100 |
| TBYC-280M-2 | 90 | 151 | 286.5 | 95.8 | 0.95 | 3000 | 100 |
| TBYC-315S-2 | 110 | 179 | 350 | 96 | 0.95 | 3000 | 200 |
| TBYC-315M-2 | 132 | 206 | 420 | 96 | 0.95 | 3000 | 200 |
| TBYC-315L1-2 | 160 | 262 | 509 | 96.2 | 0.95 | 3000 | 200 |
| TBYC-315L2-2 | 200 | 330 | 636.7 | 96.3 | 0.95 | 3000 | 150 |
| TBYC-801-4 | 0.55 | 0.96 | 3.5 | 84.5 | 0.95 | 1500 | 50 |
| TBYC-802-4 | 0.75 | 1.3 | 4.7 | 85.6 | 0.95 | 1500 | 50 |
| TBYC-90S-4 | 1.1 | 1.9 | 7 | 87.4 | 0.95 | 1500 | 50 |
| TBYC-90L-4 | 1.5 | 2.6 | 9.5 | 88.1 | 0.95 | 1500 | 50 |
| TBYC-100L1-4 | 2.2 | 3.7 | 14 | 89.7 | 0.95 | 1500 | 50 |
| TBYC-100L2-4 | 3 | 5.1 | 19.1 | 90.3 | 0.95 | 1500 | 50 |
| TBYC-112M-4 | 4 | 6.6 | 25.4 | 90.9 | 0.95 | 1500 | 50 |
| TBYC-132S-4 | 5.5 | 9 | 35 | 92.1 | 0.95 | 1500 | 50 |
| TBYC-132M-4 | 7.5 | 12.2 | 47.7 | 92.6 | 0.95 | 1500 | 50 |
| TBYC-160M-4 | 11 | 18.6 | 70 | 93.6 | 0.95 | 1500 | 50 |
| TBYC-160L-4 | 15 | 23.9 | 95.5 | 94 | 0.95 | 1500 | 50 |
| TBYC-180M-4 | 18.5 | 32 | 117.7 | 94.3 | 0.95 | 1500 | 100 |
| TBYC-180L-4 | 22 | 37 | 140 | 94.7 | 0.95 | 1500 | 100 |
| TBYC-200L-4 | 30 | 50 | 191 | 95 | 0.95 | 1500 | 100 |
| TBYC-225S-4 | 37 | 65 | 235.6 | 95.3 | 0.95 | 1500 | 100 |
| TBYC-225M-4 | 45 | 71 | 286.5 | 95.6 | 0.95 | 1500 | 100 |
| TBYC-250M-4 | 55 | 85.4 | 350 | 95.8 | 0.95 | 1500 | 100 |
| TBYC-280S-4 | 75 | 117 | 477.5 | 96 | 0.95 | 1500 | 100 |
| TBYC-280M-4 | 90 | 152 | 573 | 96.2 | 0.95 | 1500 | 100 |
| TBYC-315S-4 | 110 | 183 | 700 | 96.4 | 0.95 | 1500 | 100 |
| TBYC-315M-4 | 132 | 209 | 840.4 | 96.5 | 0.95 | 1500 | 100 |
| TBYC-315L1-4 | 160 | 260 | 1018.6 | 96.5 | 0.95 | 1500 | 100 |
| TBYC-315L2-4 | 200 | 352 | 1273.3 | 96.6 | 0.95 | 1500 | 100 |
| Motor Mode | Rated Power kW | Rated Current | Rated Torque | Efficiency (%) | Power factor | Rated speed | Rated Frequency Hz |
| TBYC-802-6 | 0.55 | 1 | 5.2 | 82.4 | 0.95 | 0 | 33.3 |
| TBYC-90S-6 | 0.75 | 1.3 | 7.2 | 86.8 | 0.95 | 1000 | 33.3 |
| TBYC-90L-6 | 1.1 | 1.9 | 10.5 | 88.2 | 0.95 | 1000 | 33.3 |
| TBYC-100L-6 | 1.5 | 2.7 | 14.3 | 89.4 | 0.95 | 1000 | 33.3 |
| TBYC-112M-6 | 2.2 | 3.9 | 21 | 90.5 | 0.95 | 1000 | 66.7 |
| TBYC-132S-6 | 3 | 5 | 28.6 | 91.5 | 0.95 | 1000 | 50 |
| TBYC-132M1-6 | 4 | 6.6 | 38.2 | 92.4 | 0.95 | 1000 | 50 |
| TBYC-132M2-6 | 5.5 | 9.5 | 52.5 | 93.1 | 0.95 | 1000 | 50 |
| TBYC-160M-6 | 7.5 | 12.5 | 71.6 | 93.7 | 0.95 | 1000 | 50 |
| TBYC-160L-6 | 11 | 18.5 | 105 | 94.3 | 0.95 | 1000 | 66.7 |
| TBYC-180L-6 | 15 | 25 | 143.3 | 94.7 | 0.95 | 1000 | 66.7 |
| TBYC-200L1-6 | 18.5 | 32 | 176.7 | 95.1 | 0.95 | 1000 | 66.7 |
| TBYC-200L2-6 | 22 | 36.5 | 210 | 95.4 | 0.95 | 1000 | 66.7 |
| TBYC-225M-6 | 30 | 49 | 286.5 | 95.7 | 0.95 | 1000 | 66.7 |
| TBYC-250M-6 | 37 | 61 | 353.3 | 95.9 | 0.95 | 1000 | 66.7 |
| TBYC-280S-6 | 45 | 71 | 430 | 96 | 0.95 | 0 | 66.7 |
| TBYC-280M-6 | 55 | 86 | 525.3 | 96.1 | 0.95 | 1000 | 66.7 |
| TBYC-315S-6 | 75 | 123 | 716.3 | 96.2 | 0.95 | 1000 | 66.7 |
| TBYC-315M-6 | 90 | 141 | 860 | 96.2 | 0.95 | 1000 | 66.7 |
| TBYC-315L1-6 | 110 | 174 | 1050.5 | 96.3 | 0.95 | 1000 | 66.7 |
| TBYC-315L2-6 | 132 | 210 | 1260.6 | 96.3 | 0.95 | 1000 | 66.7 |
| TBYC-315L3-6 | 160 | 248 | 1528 | 96.3 | 0.95 | 1000 | 66.7 |
| TBYC-315L4-6 | 200 | 320 | 1910 | 96.4 | 0.95 | 1000 | 66.7 |
| TBYC-112M-8 | 1.5 | 2.8 | 19.1 | 90 | 0.95 | 750 | 50 |
| TBYC-132S-8 | 2.2 | 3.8 | 28 | 90 | 0.95 | 750 | 37.5 |
| TBYC-132M-8 | 3 | 5.2 | 38.2 | 91 | 0.95 | 750 | 37.5 |
| TBYC-160M1-8 | 4 | 7.2 | 51 | 91.8 | 0.95 | 750 | 50 |
| TBYC-160M2-8 | 5.5 | 9.9 | 70 | 92.6 | 0.95 | 750 | 50 |
| TBYC-160L-8 | 7.5 | 13.4 | 95.5 | 93.2 | 0.95 | 750 | 50 |
| TBYC-180L-8 | 11 | 19.5 | 140 | 93.7 | 0.95 | 750 | 50 |
| TBYC-200L-8 | 15 | 26.6 | 191 | 94.2 | 0.95 | 750 | 50 |
| TBYC-225S-8 | 18.5 | 32.7 | 235.6 | 94.6 | 0.95 | 750 | 50 |
| TBYC-225M-8 | 22 | 38.3 | 280 | 94.9 | 0.95 | 750 | 50 |
| TBYC-250M-8 | 30 | 52.7 | 382 | 95.1 | 0.95 | 750 | 50 |
| TBYC-280S-8 | 37 | 65 | 471 | 95.3 | 0.95 | 750 | 50 |
| TBYC-280M-8 | 45 | 75.8 | 573 | 95.6 | 0.95 | 750 | 50 |
| TBYC-315S-8 | 55 | 96.2 | 700 | 95.6 | 0.95 | 750 | 50 |
| TBYC-315M-8 | 75 | 122 | 955 | 95.7 | 0.95 | 750 | 50 |
| TBYC-315L1-8 | 90 | 157 | 1146 | 95.7 | 0.95 | 750 | 50 |
| TBYC-315L2-8 | 110 | 185.7 | 1400 | 95.7 | 0.95 | 750 | 50 |
| TBYC-315L3-8 | 132 | 200 | 1680.8 | 95.8 | 0.95 | 750 | 50 |
| TBYC-315L4-8 | 160 | 270 | 2037 | 95.8 | 0.95 | 750 | 50 |
When the hazardous-area classification is still being established, reviewing related hazardous-area motor options may help structure the documentation request.
The installation classification and the proposed model\'s actual markings must be checked together. An explosion-proof label alone does not establish project compliance.
The specifications and included components for this exact product are described above. The guidance below supports sourcing decisions; it is not a claim that every option or capability is available for this SKU.
Identify the applicable gas or dust zone and equipment group.
Verify the model's exact Ex marking, temperature class and permitted conditions.
Define duty, speed range, acceleration and required torque.
Review supply, inverter arrangement and cable interfaces.
Confirm ambient range, cooling, mounting and surface-temperature constraints.
Request model-specific documentation and local authority or project review as applicable.
Mechanical interfaces, operating duty, cooling and controls affect whether a configuration is suitable. Use the actual model information when discussing project requirements.
Provide the site's classified zone or division and gas or dust exposure details.
Share required torque, speed, load and supply conditions.
Confirm installation envelope, cable entry and driven equipment interface.
Request exact nameplate marking, applicable certification and test evidence for the proposed model.
Approval requirements depend on the target location, hazardous-area designation and exact motor configuration. Never infer ATEX, IECEx or any other certification from the category name.
Ask for applicable model ratings and outline drawings.
Define tests and acceptance criteria appropriate to the application.
Confirm packaging, handling and destination requirements.
Provide the following operating and integration details so the proposed configuration can be evaluated.
A practical engineering procurement sequence depends on defining the application, reviewing a suitable configuration and agreeing the evidence required.
Send application and technical data.
Review candidate models, interfaces and constraints.
Agree drawings, tests and acceptance criteria if required.
Confirm quotation, scope, inspection and shipment details.
Operating limits, documented ratings, test evidence, delivery scope and quotation terms must be confirmed for the exact configuration.
Share your intended application, torque or load requirements, operating conditions, interface drawings and project timing.